Supply voltage |
24 V DC |
Yes |
permissible range, lower limit (DC) |
20.4 V |
permissible range, upper limit (DC) |
28.8 V |
Input current |
from backplane bus 5 V DC, max. |
180 mA |
Digital inputs |
from load voltage L+ (without load), max. |
4 mA/input 11 mA/relay |
Output voltage |
Power supply to the transmitters |
present |
Yes |
Power losses |
Power loss, typ. |
10 W |
Digital inputs |
Number of digital inputs |
16 |
In groups of |
2 |
Input characteristic curve in accordance with IEC 61131, type 1 |
Yes |
Number of simultaneously controllable inputs |
all mounting positions |
up to 40 °C, max. |
16 |
horizontal installation |
up to 40 °C, max. |
16 |
up to 50 °C, max. |
16 |
vertical installation |
up to 40 °C, max. |
16 |
Input voltage |
Rated value, DC |
24 V |
for signal “0″ |
5 VDC at 1 mA |
Input current |
for signal “0″, max. (permissible quiescent current) |
1 mA |
for signal “1″, min. |
2.5 mA |
for signal “1″, typ. |
4 mA; Typical |
Input delay (for rated value of input voltage) |
for standard inputs |
Parameterizable |
Yes; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 ms, selectable in groups of four |
for interrupt inputs |
Parameterizable |
Yes |
Cable length |
Cable length, shielded, max. |
500 m |
Cable length unshielded, max. |
300 m |
Digital outputs |
Number of digital outputs |
16 |
In groups of |
4 |
Product function / at the digital outputs / short-circuit protection |
No |
Short-circuit protection |
No; to be provided externally |
Switching capacity of the outputs |
with resistive load, max. |
2 A |
on lamp load, max. |
30 W with DC, 200 W with AC |
Output voltage |
Rated value (DC) |
5 to 30 V AC |
Output current |
for signal “1″ permissible range, max. |
2 A |
Output delay with resistive load |
“0″ to “1″, max. |
10 ms |
“1″ to “0″, max. |
10 ms |
Aggregate current of outputs (per group) |
horizontal installation |
up to 50 °C, max. |
8 A; Current per mass |
Relay outputs |
Number of relay outputs |
16 |
Rated input voltage of relay coil L+ (DC) |
24 V |
Number of operating cycles, max. |
mechanically 10 million, at rated load voltage 100,000 |
Switching capacity of contacts |
with inductive load, max. |
2 A |
on lamp load, max. |
30 W with DC, 200 W with AC |
with resistive load, max. |
2 A |
Cable length |
Cable length, shielded, max. |
500 m |
Cable length unshielded, max. |
150 m |
Interrupts/diagnostics/status information |
Alarms |
Alarms |
Yes |
Diagnostic alarm |
Yes |
Diagnostic messages |
Diagnostic functions |
Yes |
Diagnostics indication LED |
for status of the inputs |
Yes |
For status of the outputs |
Yes |
for maintenance |
Yes |
Status indicator digital output (green) |
Yes |
Status indicator digital input (green) |
Yes |
Galvanic isolation |
Galvanic isolation digital inputs |
between the channels, in groups of |
2 |
Galvanic isolation digital outputs |
between the channels, in groups of |
4 |
between the channels and the backplane bus |
1500 V AC for 1 minute |
Permissible potential difference |
between different circuits |
750 V AC for 1 minute |
Degree and class of protection |
IP20 |
Yes |
Standards, approvals, certificates |
CE mark |
Yes |
C-TICK |
Yes |
FM approval |
Yes |
Climatic and mechanical conditions for storage and transport |
Climatic conditions for storage and transport |
Free fall |
Drop height, max. (in packaging) |
0.3 m; five times, in dispatch package |
Temperature |
Permissible temperature range |
-40 °C to +70 °C |
Air pressure acc. to IEC 60068-2-13 |
Permissible air pressure |
1080 to 660 hPa |
Mechanical and climatic conditions during operation |
Climatic conditions in operation |
Temperature |
Permissible temperature range |
0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation |
Permissible temperature change |
5°C to 55°C, 3°C / minute |
Connection method |
required front connector |
Yes |
Mechanics/material |
Type of housing (front) |
|
Plastic |
Yes |
Dimensions |
Width |
70 mm |
Height |
100 mm |
Depth |
75 mm |
Weights |
Weight, approx. |
350 g |