Archive for the Digital signal board Category

s7 siemens 6ES7223-3BD30-0XB0 SIGNAL BOARD SB 1223

plc s7 SIMATIC S7-1200, DIGITAL I/O SB 1223, 2DI/2DQ, 24VDC 200KHZ

Input current
from backplane bus 5 V DC, typ. 50 mA
Output voltage
Power supply to the transmitters
Supply current, max. 4 mA; per channel
Power losses
Power loss, typ. 1 W
Digital inputs
Number of digital inputs 2; Current-sourcing
In groups of 1
Input characteristic curve in accordance with IEC 61131, type 1 Yes
Number of simultaneously controllable inputs
all mounting positions
up to 40 °C, max. 2
Input voltage
Rated value, DC 24 V
for signal “0″ 0 to 5 V
for signal “1″ 15 to 30 V
Input current
for signal “0″, max. (permissible quiescent current) 2 mA
for signal “1″, min. 5.8 mA
for signal “1″, typ. 14 mA
Input delay (for rated value of input voltage)
for standard inputs
Parameterizable Yes; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 ms, selectable in groups of four
at “0″ to “1″, max. 2.5 µs
for interrupt inputs
Parameterizable Yes
for counter/technological functions
Parameterizable Yes
Cable length
Cable length, shielded, max. Standard input: 500 m, high-speed counters: 50 m
Digital outputs
Number of digital outputs 2; MOSFET, solid-state (current-sinking/current-sourcing)
In groups of 1
Product function / at the digital outputs / short-circuit protection No
Switching capacity of the outputs
with resistive load, max. 0.1 A
Load resistance range
upper limit 10 Ω
Output voltage
Rated value (DC) 24 V
for signal “0″, max. 0.1 V; with 10 kOhm load
for signal “1″, min. 20 V
Output current
for signal “1″ rated value 0.1 A
for signal “0″ residual current, max. 10 µA
Cable length
Cable length, shielded, max. 50 m
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic messages
Diagnostic functions Yes
Diagnostics indication LED
for status of the inputs Yes
For status of the outputs Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
Marine approval according to Germanischer Lloyd Yes
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 38 mm
Height 62 mm
Depth 21 mm
Weights
Weight, approx. 40 g

plc siemens s7 6ES7223-0BD30-0XB0 SIGNAL BOARD SB1223 2 DI/2 DO

siemens 1200 SIMATIC S7-1200, DIGITAL I/O SB 1223, 2 DI / 2 DO, 2 DI 24V DC/2 DO 24V DC

Supply voltage
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 30 V
Input current
from backplane bus 5 V DC, typ. 50 mA
Output voltage
Power supply to the transmitters
Supply current, max. 4 mA; per channel
Power losses
Power loss, typ. 1 W
Digital inputs
Number of digital inputs 2; Current-sinking
In groups of 1
Input characteristic curve in accordance with IEC 61131, type 1 Yes
Number of simultaneously controllable inputs
all mounting positions
up to 40 °C, max. 2
Input voltage
Rated value, DC 24 V
for signal “0″ 0 to 5 V
for signal “1″ 15 to 30 V
Input current
for signal “0″, max. (permissible quiescent current) 1 mA
for signal “1″, typ. 0.5 A
Input delay (for rated value of input voltage)
for standard inputs
Parameterizable Yes; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 ms, selectable in groups of four
at “0″ to “1″, max. 2 µs
at “1″ to “0″, max. 10 µs
for interrupt inputs
Parameterizable Yes
for counter/technological functions
Parameterizable Yes
Cable length
Cable length, shielded, max. 500 m
Cable length unshielded, max. 300 m
Digital outputs
Number of digital outputs 2; MOSFET, solid-state (current-sinking/current-sourcing)
In groups of 1
Product function / at the digital outputs / short-circuit protection No
Switching capacity of the outputs
with resistive load, max. 0.5 A
on lamp load, max. 5 W
Load resistance range
upper limit 0.6 Ω
Output voltage
Rated value (DC) 24 V
for signal “0″, max. 0.1 V; with 10 kOhm load
for signal “1″, min. 20 V
Output current
for signal “1″ rated value 0.5 A
for signal “0″ residual current, max. 10 µA
Cable length
Cable length, shielded, max. 500 m
Cable length unshielded, max. 150 m
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic messages
Diagnostic functions Yes
Diagnostics indication LED
for status of the inputs Yes
For status of the outputs Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
Marine approval according to Germanischer Lloyd Yes
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 38 mm
Height 62 mm
Depth 21 mm
Weights
Weight, approx. 40 g

siemens simatics 6ES7 221-3AD30-0XB0 SIGNAL BOARD SB 1221

Siemens SIMATIC S7-1200, DIGITAL INPUT SB 1221, 4DI, 5VDC 200KHZ

Input current
from backplane bus 5 V DC, typ. 50 mA
Output voltage
Power supply to the transmitters
Supply current, max. 4 mA; per channel
Power losses
Power loss, typ. 1 W
Digital inputs
Number of digital inputs 4; Current-sourcing
In groups of 1
Input characteristic curve in accordance with IEC 61131, type 1 Yes
Number of simultaneously controllable inputs
all mounting positions
up to 40 °C, max. 4
Input voltage
Rated value, DC 5 V
for signal “0″ 0 to 1 V
for signal “1″ 2 to 6 V
Input current
for signal “0″, max. (permissible quiescent current) 3 mA
for signal “1″, min. 6 mA
Input delay (for rated value of input voltage)
for standard inputs
Parameterizable Yes; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 ms, selectable in groups of four
at “0″ to “1″, max. 2 µs
for interrupt inputs
Parameterizable Yes
for counter/technological functions
Parameterizable Yes
Cable length
Cable length, shielded, max. 50 m; Shielded, twisted wire pair
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic messages
Diagnostic functions Yes
Diagnostics indication LED
for status of the inputs Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
Marine approval according to Germanischer Lloyd Yes
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 38 mm
Height 62 mm
Depth 21 mm
Weights
Weight, approx. 40 g

siemens s 7 6ES7221-3BD30-0XB0 SIGNAL BOARD SB 1221

simatic s7 plc 6ES7221-3BD30-0XB0

SIGNAL BOARD SB 1221, 4 DI 24VDC 200KHZ

Input current
from backplane bus 5 V DC, typ. 50 mA
Output voltage
Power supply to the transmitters
Supply current, max. 4 mA; per channel
Power losses
Power loss, typ. 1 W
Digital inputs
Number of digital inputs 4; Current-sourcing
In groups of 1
Input characteristic curve in accordance with IEC 61131, type 2 Yes
Number of simultaneously controllable inputs
all mounting positions
up to 40 °C, max. 4
Input voltage
Rated value, DC 24 V
for signal “0″ 0 to 5 V
for signal “1″ 15 to 30 V
Input current
for signal “0″, max. (permissible quiescent current) 2 mA
for signal “1″, min. 5.8 mA
for signal “1″, typ. 14 mA
Input delay (for rated value of input voltage)
for standard inputs
Parameterizable Yes; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 ms, selectable in groups of four
at “0″ to “1″, max. 2.5 µs
for interrupt inputs
Parameterizable Yes
for counter/technological functions
Parameterizable Yes
Cable length
Cable length, shielded, max. 50 m; Standard input: 500 m, high-speed counters: 50 m
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic messages
Diagnostic functions Yes
Diagnostics indication LED
for status of the inputs Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
Marine approval according to Germanischer Lloyd Yes
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 38 mm
Height 62 mm
Depth 21 mm
Weights
Weight, approx. 40 g