s7 siemens 6ES7215-1HG31-0XB0 CPU 1215C, DC/DC/RLY, 14DI/10DO/2AI/2AO
siemens plc s7 SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20,4 -28,8 V DC, PROGRAM/DATA MEMORY: 100 KB
General information | |
Engineering with | |
Programming package | As of STEP 7 V11.0 SP2 |
Supply voltage | |
24 V DC | Yes |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Load voltage L+ | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 5 V |
permissible range, upper limit (DC) | 250 V |
Input current | |
Current consumption (rated value) | 500 mA; Typical |
Current consumption, max. | 1500 A; 24 V DC |
Inrush current, max. | 12 A; at 28.8 V DC |
Output current | |
Current output to backplane bus (DC 5 V), max. | 1600 mA; Max. 5 V DC for SM and CM |
Power losses | |
Power loss, typ. | 12 W |
Memory | |
Usable memory for user data | 100 kbyte |
Work memory | |
integrated | 100 kbyte |
expandable | No |
Load memory | |
integrated | 4 Mbyte |
Backup | |
present | Yes; (maintenance-free) |
without battery | Yes |
CPU processing times | |
for bit operations, typ. | 0.085 µs; / instruction |
for word operations, typ. | 1.7 µs; / instruction |
for floating point arithmetic, typ. | 2.5 µs; / instruction |
CPU-blocks | |
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
OB | |
Number, max. | Limited only by RAM for code |
Data areas and their retentivity | |
retentive data area in total (incl. times, counters, flags), max. | 10 kbyte |
Flag | |
Number, max. | 8 kbyte; Size of bit memory address area |
Address area | |
I/O address area | |
I/O address area, overall | 1024 bytes for inputs / 1024 bytes for outputs |
Process image | |
Inputs, adjustable | 1 kbyte |
Outputs, adjustable | 1 kbyte |
Hardware configuration | |
Number of modules per system, max. | 3 comm. modules, 1 signal board, 8 signal modules |
Time of day | |
Clock | |
Hardware clock (real-time clock) | Yes |
Deviation per day, max. | +/- 60 s/month at 25 °C |
Backup time | 480 h; Typical |
Digital inputs | |
Number of digital inputs | 14; integrated |
of which, inputs usable for technological functions | 6; HSC (High Speed Counting) |
integrated channels (DI) | 14 |
m/p-reading | Yes |
Number of simultaneously controllable inputs | |
all mounting positions | |
up to 40 °C, max. | 14 |
Input voltage | |
Rated value, DC | 24 V |
for signal “0″ | 5 VDC at 1 mA |
for signal “1″ | 15 V DC at 2.5 mA |
Input current | |
for signal “1″, typ. | 1 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
Parameterizable | Yes; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 ms, selectable in groups of four |
at “0″ to “1″, min. | 0.2 ms |
at “0″ to “1″, max. | 12.8 ms |
for interrupt inputs | |
Parameterizable | Yes |
for counter/technological functions | |
Parameterizable | Yes; Single phase : 3 at 100 kHz & 3 at 30 kHz, differential: 3 at 80 kHz & 3 at 30 kHz |
Cable length | |
Cable length, shielded, max. | 500 m; 50 m for technological functions |
Cable length unshielded, max. | 300 m; For technological functions: No |
Digital outputs | |
Number of digital outputs | 10 |
integrated channels (DO) | 10 |
Product function / at the digital outputs / short-circuit protection | No |
Switching capacity of the outputs | |
with resistive load, max. | 2 A |
on lamp load, max. | 30 W with DC, 200 W with AC |
Output delay with resistive load | |
“0″ to “1″, max. | 10 ms; max. |
“1″ to “0″, max. | 10 ms; max. |
Switching frequency | |
of the pulse outputs, with resistive load, max. | 1 Hz |
Relay outputs | |
Number of relay outputs | 10 |
Number of operating cycles, max. | mechanically 10 million, at rated load voltage 100,000 |
Cable length | |
Cable length, shielded, max. | 500 m |
Cable length unshielded, max. | 150 m |
Analog inputs | |
Integrated channels (AI) | 2; 0 to 10 V |
Number of analog inputs | 2 |
Input ranges | |
Voltage | Yes |
Input ranges (rated values), voltages | |
0 to +10 V | Yes |
Input resistance (0 to 10 V) | ≥100k ohms |
Cable length | |
Cable length, shielded, max. | 100 m; twisted and shielded |
Analog outputs | |
Integrated channels (AO) | 2; 0 to 20mA |
Number of analog outputs | 2 |
Cable length | |
Cable length, shielded, max. | 100 m |
Analog value creation | |
Integrations and conversion time/ resolution per channel | |
Resolution with overrange (bit including sign), max. | 10 bit |
Integration time, parameterizable | Yes |
Conversion time (per channel) | 625 µs |
Encoder | |
Connectable encoders | |
2-wire sensor | Yes |
1st interface | |
Type of interface | PROFINET |
Physics | Ethernet |
Isolated | Yes |
Automatic detection of transmission speed | Yes |
Autonegotiation | Yes |
Autocrossing | Yes |
Functionality | |
PROFINET IO Controller | Yes |
Communication functions | |
S7 communication | |
supported | Yes |
as server | Yes |
as client | Yes |
Open IE communication | |
TCP/IP | Yes |
ISO-on-TCP (RFC1006) | Yes |
UDP | Yes |
Web server | |
supported | Yes |
User-defined websites | Yes |
Test commissioning functions | |
Status/control | |
Status/control variable | Yes |
Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
Forcing | |
Forcing | Yes |
Diagnostic buffer | |
present | Yes |
Integrated Functions | |
Number of counters | 6 |
Counter frequency (counter) max. | 100 kHz |
Frequency meter | Yes |
controlled positioning | Yes |
PID controller | Yes |
Number of alarm inputs | 4 |
Number of pulse outputs | 4 |
Galvanic isolation | |
Galvanic isolation digital inputs | |
Galvanic isolation digital inputs | 500 V AC for 1 minute |
between the channels, in groups of | 1 |
Galvanic isolation digital outputs | |
between the channels | No |
Permissible potential difference | |
between different circuits | 500 V DC between 24 V DC and 5 V DC |
EMC | |
Interference immunity against discharge of static electricity | |
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
Test voltage at air discharge | 8 kV |
Test voltage at contact discharge | 6 kV |
Interference immunity to cable-borne interference | |
on the supply lines acc. to IEC 61000-4-4 | Yes |
Interference immunity on signal lines acc. to IEC 61000-4-4 | Yes |
Surge immunity | |
on the supply lines acc. to IEC 61000-4-5 | Yes |
Immunity against conducted interference induced by high-frequency fields | |
Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes |
Emission of radio interference acc. to EN 55 011 | |
Emission of radio interferences acc. to EN 55 011 (limit class A) | Yes; Group 1 |
Emission of radio interference acc. to EN 55 011 (limit class B) | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
Degree and class of protection | |
IP20 | Yes |
Standards, approvals, certificates | |
CE mark | Yes |
CSA approval | Yes |
UL approval | Yes |
cULus | Yes |
C-TICK | Yes |
FM approval | Yes |
Marine approval | Yes |
Ambient conditions | |
Operating temperature | |
Min. | -20 °C |
max. | 60 °C |
horizontal installation, min. | -20 °C |
horizontal installation, max. | 60 °C |
vertical installation, min. | -20 °C |
vertical installation, max. | 50 °C |
Storage/transport temperature | |
Min. | -40 °C |
max. | 70 °C |
Air pressure | |
Operation, min. | 795 hPa |
Operation, max. | 1080 hPa |
Storage/transport, min. | 660 hPa |
Storage/transport, max. | 1080 hPa |
Relative humidity | |
Operation, max. | 95 %; no condensation |
Vibrations | |
Vibrations | 2G wall mounting, 1G DIN rail |
Operation, checked according to IEC 60068-2-6 | Yes |
Shock test | |
checked according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
Climatic and mechanical conditions for storage and transport | |
Climatic conditions for storage and transport | |
Free fall | |
Drop height, max. (in packaging) | 0.3 m; five times, in dispatch package |
Temperature | |
Permissible temperature range | -40 °C to +70 °C |
Mechanical and climatic conditions during operation | |
Climatic conditions in operation | |
Temperature | |
Min. | -20 °C |
max. | 60 °C |
Air pressure acc. to IEC 60068-2-13 | |
Permissible air pressure | 1080 to 795 hPa |
Permissible operating height | -1000 to 2000 m |
Pollutant concentrations | |
SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
Configuration | |
programming | |
Programming language | |
LAD | Yes |
FBD | Yes |
SCL | Yes |
Cycle time monitoring | |
adjustable | Yes |
Dimensions | |
Width | 130 mm |
Height | 100 mm |
Depth | 75 mm |
Weights | |
Weight, approx. | 585 g |