6ES7234-4HE30-0XB0 ANALOG I/O module SM 1234

siemens programming 6ES7234-4HE30-0XB0

ANALOG I/O SM 1234, 4AI/2AO

s7 programming SIMATIC S7-1200, ANALOG I/O SM 1234, 4 AI / 2 AO, +/-10V, 14 BIT RESOLUTION, OR 0-20 MA, 13 BIT RESOLUTION

Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 60 mA
from backplane bus 5 V DC, typ. 80 mA
Power losses
Power loss, typ. 2 W
Analog inputs
Number of analog inputs 4; Current or voltage differential inputs
permissible input frequency for current input (destruction limit), max. ± 35 V
permissible input voltage for voltage input (destruction limit), max. 35 V
permissible input current for voltage input (destruction limit), max. 40 mA
permissible input current for current input (destruction limit), max. 40 mA
Cycle time (all channels) max. 625 µs
Input ranges
Voltage Yes; ±10 V, ±5 V, ±2.5 V
Current Yes; 0 to 20 mA
Thermocouple No
Resistance thermometer No
Resistance No
Input ranges (rated values), voltages
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) ≥9 MOhm
-2.5 V to +2.5 V Yes
Input resistance (-2.5 V to +2.5 V) ≥9 MOhm
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) ≥9 MOhm
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 280 Ω
Thermocouple (TC)
Temperature compensation
Parameterizable No
Analog outputs
Number of analog outputs 2; Current or voltage
Output ranges, voltage
-10 to +10 V Yes
Output ranges, current
0 to 20 mA Yes
Load impedance (in rated range of output)
with voltage outputs, min. 1000 Ω
with current outputs, max. 600 Ω
Analog value creation
Measurement principle Differential
Integrations and conversion time/ resolution per channel
Resolution (incl. overrange) Voltage: 14 bits; Current : 13 bits
Integration time, parameterizable Yes
Interference voltage suppression for interference frequency f1 in Hz 40 dB, DC to 60 V for interference frequency 50 / 60 Hz
Smoothing of measured values
Parameterizable Yes
Step: None Yes
Step: low Yes
Step: Medium Yes
Step: High Yes
Errors/accuracies
Temperature error (relative to input area) 25 °C ±0.1 % to 55 °C ±0.2 % total measurement range
Temperature error (relative to output area) 25 °C ±0.3% to 55 °C ±0.6% total measurement range
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area +/- 0.1 %
Current, relative to input area +/- 0.1 %
Voltage, relative to output area +/- 0.3 %
Current, relative to output area +/- 0.3 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
common mode voltage, max. 12 V
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic alarm Yes
Diagnostic messages
Diagnostic functions Yes
Monitoring the supply voltage Yes
Wire break Yes
Short circuit Yes
Diagnostics indication LED
for status of the inputs Yes
For status of the outputs Yes
for maintenance Yes
Galvanic isolation
Galvanic isolation analog outputs
between the channels and the power supply of the electronics No
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
CE mark Yes
C-TICK Yes
FM approval Yes
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 795 hPa
Pollutant concentrations
SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Connection method
required front connector Yes
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 45 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 220 g

siemens plc 1200 6ES7 232-4HD30-0XB0 ANALOG OUTPUT SM 1232

siemens controllers 6ES7232-4HD30-0XB0

ANALOG OUTPUT SM 1232, 4AO

siemens programming SIMATIC S7-1200, ANALOG OUTPUT, SM 1232, 4 AO, +/-10V, 14 BIT RESOLUTION, OR 0-20 MA, 13 BIT RESOLUTION

Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 45 mA
from backplane bus 5 V DC, typ. 80 mA
Power losses
Power loss, typ. 1.5 W
Analog inputs
Number of analog inputs 0
Thermocouple (TC)
Temperature compensation
Parameterizable No
Analog outputs
Number of analog outputs 4; Current or voltage
Output ranges, voltage
-10 to +10 V Yes
Output ranges, current
0 to 20 mA Yes
Load impedance (in rated range of output)
with voltage outputs, min. 1000 Ω
with current outputs, max. 600 Ω
Analog value creation
Measurement principle Differential
Integrations and conversion time/ resolution per channel
Resolution (incl. overrange) Voltage: 14 bits; Current : 13 bits
Integration time, parameterizable Yes
Interference voltage suppression for interference frequency f1 in Hz 40 dB, DC to 60 V for interference frequency 50 / 60 Hz
Errors/accuracies
Temperature error (relative to output area) 25 °C ±0.3% to 55 °C ±0.6% total measurement range
Basic error limit (operational limit at 25 °C)
Voltage, relative to output area +/- 0.3 %
Current, relative to output area +/- 0.3 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
common mode voltage, max. 12 V
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic alarm Yes
Diagnostic messages
Diagnostic functions Yes
Monitoring the supply voltage Yes
Wire break Yes
Short circuit Yes
Diagnostics indication LED
For status of the outputs Yes
for maintenance Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
CE mark Yes
C-TICK Yes
FM approval Yes
Highest safety class achievable in safety mode
acc. to IEC 61508 none
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 795 hPa
Pollutant concentrations
SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Connection method
required front connector Yes
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 45 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 180 g

programmazione plc siemens 6ES7 232-4HB30-0XB0 SM 1232 2AO

s7 simatic 6ES7232-4HB30-0XB0

ANALOG OUTPUT SM 1232, 2AO

automatas programables siemens SIMATIC S7-1200, ANALOG OUTPUT, SM 1232, 2 AO, +/-10V, 14 BIT RESOLUTION, OR 0-20 MA, 13 BIT RESOLUTION

Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 45 mA
from backplane bus 5 V DC, typ. 80 mA
Power losses
Power loss, typ. 1.5 W
Analog inputs
Number of analog inputs 0
Thermocouple (TC)
Temperature compensation
Parameterizable No
Analog outputs
Number of analog outputs 2; Current or voltage
Output ranges, voltage
-10 to +10 V Yes
Output ranges, current
0 to 20 mA Yes
Load impedance (in rated range of output)
with voltage outputs, min. 1000 Ω
with current outputs, max. 600 Ω
Analog value creation
Measurement principle Differential
Integrations and conversion time/ resolution per channel
Resolution (incl. overrange) Voltage: 14 bits; Current : 13 bits
Integration time, parameterizable Yes
Interference voltage suppression for interference frequency f1 in Hz 40 dB, DC to 60 V for interference frequency 50 / 60 Hz
Errors/accuracies
Temperature error (relative to output area) 25 °C ±0.3% to 55 °C ±0.6% total measurement range
Basic error limit (operational limit at 25 °C)
Voltage, relative to output area +/- 0.3 %
Current, relative to output area +/- 0.3 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
common mode voltage, max. 12 V
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic alarm Yes
Diagnostic messages
Diagnostic functions Yes
Monitoring the supply voltage Yes
Wire break Yes
Short circuit Yes
Diagnostics indication LED
For status of the outputs Yes
for maintenance Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
CE mark Yes
C-TICK Yes
FM approval Yes
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 795 hPa
Pollutant concentrations
SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Connection method
required front connector Yes
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 45 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 180 g

plcs siemens 6ES7231-5QF30-0XB0 ANALOG INPUT SM 1231 TC

siemens s7 programmierung 6ES7231-5QF30-0XB0

S7-1200, ANALOG INPUT SM 1231 TC, 8 AI

automatas programables siemens SIMATIC S7-1200, ANALOG INPUT, SM 1231 TC, 8 AI THERMOCOUPLE

Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 80 mA
from backplane bus 5 V DC, typ. 80 mA
Power losses
Power loss, typ. 1.5 W
Analog inputs
Number of analog inputs 8; Thermocouples
permissible input frequency for current input (destruction limit), max. ± 35 V
Technical unit for temperature measurement adjustable Degrees Celsius/degrees Fahrenheit
Input ranges
Thermocouple Yes; J, K, T, E, R, S, N, C, TXK/XK(L); voltage range: +/-80 mV
Resistance thermometer No
Resistance Yes
Input ranges (rated values), voltages
-80 mV to +80 mV Yes
Input ranges (rated values), thermoelements
Type C Yes
Type E Yes
Type J Yes
Type K Yes
Type N Yes
Type R Yes
Type S Yes
Type T Yes
Type TXK/TXK(L) to GOST Yes
Thermocouple (TC)
permissible input voltage for voltage input (destruction limit), max. +-35V
Temperature compensation
Parameterizable No
Analog outputs
Number of analog outputs 0
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 15 bit; + sign
Integration time, parameterizable No
Interference voltage suppression for interference frequency f1 in Hz 85 dB at 50 / 60 / 400 Hz
Analog value generation (in isochronous mode)
Smoothing of measured values
Parameterizable Yes
Errors/accuracies
cold connection point +/-1.5 °C
Temperature error (relative to input area) 25 °C ±0.1 % to 55 °C ±0.2 % total measurement range
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Common mode interference, min. 120 dB
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic alarm Yes
Diagnostic messages
Diagnostic functions Yes; Can be read out
Monitoring the supply voltage Yes
Wire break Yes
Diagnostics indication LED
for status of the inputs Yes
for maintenance Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
CE mark Yes
C-TICK Yes
FM approval Yes
Highest safety class achievable in safety mode
acc. to IEC 61508 none
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 795 hPa
Pollutant concentrations
SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Connection method
required front connector Yes
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 45 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 220 g

plc equipment 6ES7231-5PF30-0XB0 S7-1200 SM 1231 RTD

s7 1200 plc 6ES7231-5PF30-0XB0 S7-1200, ANALOG INPUT SM 1231 RTD, 8 AI
industrial plc SIMATIC S7-1200, ANALOG INPUT, SM 1231RTD, 8 X AI RTD MODULE,
Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 90 mA
from backplane bus 5 V DC, typ. 80 mA
Power losses
Power loss, typ. 1.5 W
Analog inputs
Number of analog inputs 8; Resistance thermometer
permissible input frequency for current input (destruction limit), max. ± 35 V
Technical unit for temperature measurement adjustable Degrees Celsius/degrees Fahrenheit
Input ranges
Thermocouple No
Resistance thermometer Yes; Resistance-type transmitter: Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10, Cu50, Cu100, LG-Ni1000
Resistance Yes; 150 Ω, 300 Ω, 600 Ω
Input ranges (rated values), resistance thermometers
Cu 10 Yes
Input resistance (Cu 10) 10 Ω
Ni 100 Yes
Input resistance (Ni 100) 100 Ω
Ni 1000 Yes
Input resistance (Ni 1000) 1000 Ω
LG-Ni 1000 Yes
Input resistance (LG-Ni 1000) 1000 Ω
Ni 120 Yes
Input resistance (Ni 120) 120 Ω
Ni 200 Yes
Input resistance (Ni 200) 200 Ω
Ni 500 Yes
Input resistance (Ni 500) 500 Ω
Pt 100 Yes
Input resistance (Pt 100) 100 Ω
Pt 1000 Yes
Input resistance (Pt 1000) 1000 Ω
Pt 200 Yes
Input resistance (Pt 200) 200 Ω
Pt 500 Yes
Input resistance (Pt 500) 500 Ω
Input ranges (rated values), resistors
0 to 150 ohms Yes
0 to 300 ohms Yes
0 to 600 ohms Yes
Thermocouple (TC)
Temperature compensation
Parameterizable No
Analog outputs
Number of analog outputs 0
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 15 bit; + sign
Integration time, parameterizable No
Interference voltage suppression for interference frequency f1 in Hz 85 dB at 10 / 50 / 60 / 400 Hz
Errors/accuracies
cold connection point +/-1.5 °C
Temperature error (relative to input area) 25 °C ±0.1 % to 55 °C ±0.2 % total measurement range
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Common mode interference, min. 120 dB
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic alarm Yes
Diagnostic messages
Diagnostic functions Yes; Can be read out
Monitoring the supply voltage Yes
Wire break Yes
Diagnostics indication LED
for status of the inputs Yes
for maintenance Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
CE mark Yes
C-TICK Yes
FM approval Yes
Highest safety class achievable in safety mode
acc. to IEC 61508 none
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 795 hPa
Pollutant concentrations
SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Connection method
required front connector Yes
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 70 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 220 g

siemens s7 programming 6ES7 231-5QD30-0XB0 S7-1200 SM 1231 TC

compact plc 6ES7231-5QD30-0XB0 S7-1200, ANALOG INPUT SM 1231 TC, 4 AI
s7 1200 plc SIMATIC S7-1200, ANALOG INPUT, SM 1231 TC, 4 AI THERMOCOUPLE
Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 40 mA
from backplane bus 5 V DC, typ. 80 mA
Power losses
Power loss, typ. 1.5 W
Analog inputs
Number of analog inputs 4; Thermocouples
permissible input frequency for current input (destruction limit), max. ± 35 V
Technical unit for temperature measurement adjustable Degrees Celsius/degrees Fahrenheit
Input ranges
Thermocouple Yes; J, K, T, E, R, S, N, C, TXK/XK(L); voltage range: +/-80 mV
Resistance thermometer No
Resistance Yes
Input ranges (rated values), voltages
-80 mV to +80 mV Yes
Input ranges (rated values), thermoelements
Type C Yes
Type E Yes
Type J Yes
Type K Yes
Type N Yes
Type R Yes
Type S Yes
Type T Yes
Type TXK/TXK(L) to GOST Yes
Thermocouple (TC)
permissible input voltage for voltage input (destruction limit), max. +-35V
Temperature compensation
Parameterizable No
Analog outputs
Number of analog outputs 0
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 15 bit; + sign
Integration time, parameterizable No
Interference voltage suppression for interference frequency f1 in Hz 85 dB at 50 / 60 / 400 Hz
Analog value generation (in isochronous mode)
Smoothing of measured values
Parameterizable Yes
Errors/accuracies
Temperature error (relative to input area) 25 °C ±0.1 % to 55 °C ±0.2 % total measurement range
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Common mode interference, min. 120 dB
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic alarm Yes
Diagnostic messages
Diagnostic functions Yes; Can be read out
Monitoring the supply voltage Yes
Wire break Yes
Diagnostics indication LED
for status of the inputs Yes
for maintenance Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
CE mark Yes
C-TICK Yes
FM approval Yes
Highest safety class achievable in safety mode
acc. to IEC 61508 none
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 795 hPa
Pollutant concentrations
SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Connection method
required front connector Yes
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 45 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 180 g

plc industrial 6ES7 231-5PD30-0XB0 S7-1200 SM 1231 RTD

simatic plc 6ES7231-5PD30-0XB0  S7-1200, ANALOG INPUT SM 1231 RTD, 4 AI
programa plc SIMATIC S7-1200, ANALOG INPUT, SM 1231 RTD, 4 X AI RTD MODULE
Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 40 mA
from backplane bus 5 V DC, typ. 80 mA
Power losses
Power loss, typ. 1.5 W
Analog inputs
Number of analog inputs 4; Resistance thermometer
permissible input frequency for current input (destruction limit), max. ± 35 V
Technical unit for temperature measurement adjustable Degrees Celsius/degrees Fahrenheit
Input ranges
Thermocouple No
Resistance thermometer Yes; Resistance-type transmitter: Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10, Cu50, Cu100, LG-Ni1000
Resistance Yes; 150 Ω, 300 Ω, 600 Ω
Input ranges (rated values), resistance thermometers
Cu 10 Yes
Input resistance (Cu 10) 10 Ω
Ni 100 Yes
Input resistance (Ni 100) 100 Ω
Ni 1000 Yes
Input resistance (Ni 1000) 1000 Ω
LG-Ni 1000 Yes
Input resistance (LG-Ni 1000) 1000 Ω
Ni 120 Yes
Input resistance (Ni 120) 120 Ω
Ni 200 Yes
Input resistance (Ni 200) 200 Ω
Ni 500 Yes
Input resistance (Ni 500) 500 Ω
Pt 100 Yes
Input resistance (Pt 100) 100 Ω
Pt 1000 Yes
Input resistance (Pt 1000) 1000 Ω
Pt 200 Yes
Input resistance (Pt 200) 200 Ω
Pt 500 Yes
Input resistance (Pt 500) 500 Ω
Input ranges (rated values), resistors
0 to 150 ohms Yes
0 to 300 ohms Yes
0 to 600 ohms Yes
Thermocouple (TC)
Temperature compensation
Parameterizable No
Analog outputs
Number of analog outputs 0
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 15 bit; + sign
Integration time, parameterizable No
Interference voltage suppression for interference frequency f1 in Hz 85 dB at 50 / 60 / 400 Hz
Errors/accuracies
Temperature error (relative to input area) 25 °C ±0.1 % to 55 °C ±0.2 % total measurement range
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Common mode interference, min. 120 dB
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic alarm Yes
Diagnostic messages
Diagnostic functions Yes; Can be read out
Monitoring the supply voltage Yes
Wire break Yes
Diagnostics indication LED
for status of the inputs Yes
for maintenance Yes
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
CE mark Yes
C-TICK Yes
FM approval Yes
Highest safety class achievable in safety mode
acc. to IEC 61508 none
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 795 hPa
Pollutant concentrations
SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Connection method
required front connector Yes
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 45 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 220 g

siemens 1200 plc 6ES7 231-4HF30-0XB0 ANALOG INPUT

siemens plcs 6ES7231-4HF30-0XB0 ANALOG INPUT SM 1231, 8AI
curso de plc siemens SIMATIC S7-1200, ANALOG INPUT, SM 1231, 8 AI, +/-10V, +/-5V, +/-2.5V, OR 0-20 MA 12 BIT + SIGN OR (13 BIT ADC)
Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 45 mA
from backplane bus 5 V DC, typ. 90 mA
Power losses
Power loss, typ. 1.5 W
Analog inputs
Number of analog inputs 8; Current or voltage differential inputs
permissible input frequency for current input (destruction limit), max. ± 35 V
permissible input voltage for voltage input (destruction limit), max. 35 V
permissible input current for voltage input (destruction limit), max. 40 mA
permissible input current for current input (destruction limit), max. 40 mA
Cycle time (all channels) max. 625 µs
Input ranges
Voltage Yes; ±10 V, ±5 V, ±2.5 V
Current Yes; 0 to 20 mA
Thermocouple No
Resistance thermometer No
Resistance No
Input ranges (rated values), voltages
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) ≥9 MOhm
-2.5 V to +2.5 V Yes
Input resistance (-2.5 V to +2.5 V) ≥9 MOhm
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) ≥9 MOhm
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 280 Ω
Thermocouple (TC)
Temperature compensation
Parameterizable No
Analog outputs
Number of analog outputs 0
Analog value creation
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 12 bit; + sign
Integration time, parameterizable Yes
Interference voltage suppression for interference frequency f1 in Hz 40 dB, DC to 60 V for interference frequency 50 / 60 Hz
Smoothing of measured values
Parameterizable Yes
Step: None Yes
Step: low Yes
Step: Medium Yes
Step: High Yes
Errors/accuracies
Temperature error (relative to input area) 25 °C ±0.1 % to 55 °C ±0.2 % total measurement range
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area +/- 0.1 %
Current, relative to input area +/- 0.1 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
common mode voltage, max. 12 V
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic alarm Yes
Diagnostic messages
Diagnostic functions Yes
Monitoring the supply voltage Yes
Wire break No
Diagnostics indication LED
for status of the inputs Yes
for maintenance Yes
Galvanic isolation
Galvanic isolation analog outputs
between the channels and the power supply of the electronics No
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
CE mark Yes
C-TICK Yes
FM approval Yes
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 795 hPa
Pollutant concentrations
SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Connection method
required front connector Yes
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 45 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 180 g

siemens 1200 plc 6ES7231-4HD30-0XB0 ANALOG INPUT SM 1231

programacion plc siemens 6ES7231-4HD30-0XB0 ANALOG INPUT SM 1231, 4AI
small plc SIMATIC S7-1200, ANALOG INPUT, SM 1231, 4 AI, +/-10V, +/-5V, +/-2.5V, OR 0-20 MA 12 BIT + SIGN BIT (13 BIT ADC)
Supply voltage
24 V DC Yes
Input current
Current consumption, typ. 45 mA
from backplane bus 5 V DC, typ. 80 mA
Power losses
Power loss, typ. 1.5 W
Analog inputs
Number of analog inputs 4; Current or voltage differential inputs
permissible input frequency for current input (destruction limit), max. ± 35 V
permissible input voltage for voltage input (destruction limit), max. 35 V
permissible input current for voltage input (destruction limit), max. 40 mA
permissible input current for current input (destruction limit), max. 40 mA
Cycle time (all channels) max. 625 µs
Input ranges
Voltage Yes; ±10 V, ±5 V, ±2.5 V
Current Yes; 0 to 20 mA
Thermocouple No
Resistance thermometer No
Resistance No
Input ranges (rated values), voltages
-10 V to +10 V Yes
Input resistance (-10 V to +10 V) ≥9 MOhm
-2.5 V to +2.5 V Yes
Input resistance (-2.5 V to +2.5 V) ≥9 MOhm
-5 V to +5 V Yes
Input resistance (-5 V to +5 V) ≥9 MOhm
Input ranges (rated values), currents
0 to 20 mA Yes
Input resistance (0 to 20 mA) 280 Ω
Thermocouple (TC)
Temperature compensation
Parameterizable No
Analog outputs
Number of analog outputs 0
Analog value creation
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 12 bit; + sign
Integration time, parameterizable Yes
Interference voltage suppression for interference frequency f1 in Hz 40 dB, DC to 60 V for interference frequency 50 / 60 Hz
Smoothing of measured values
Parameterizable Yes
Step: None Yes
Step: low Yes
Step: Medium Yes
Step: High Yes
Errors/accuracies
Temperature error (relative to input area) 25 °C ±0.1 % to 55 °C ±0.2 % total measurement range
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area +/- 0.1 %
Current, relative to input area +/- 0.1 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
common mode voltage, max. 12 V
Interrupts/diagnostics/status information
Alarms
Alarms Yes
Diagnostic alarm Yes
Diagnostic messages
Diagnostic functions Yes
Monitoring the supply voltage Yes
Wire break No
Diagnostics indication LED
for status of the inputs Yes
for maintenance Yes
Galvanic isolation
Galvanic isolation analog outputs
between the channels and the power supply of the electronics No
Degree and class of protection
IP20 Yes
Standards, approvals, certificates
CE mark Yes
C-TICK Yes
FM approval Yes
Climatic and mechanical conditions for storage and transport
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging) 0.3 m; five times, in dispatch package
Temperature
Permissible temperature range -40 °C to +70 °C
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 660 hPa
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Permissible temperature range 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation
Air pressure acc. to IEC 60068-2-13
Permissible air pressure 1080 to 795 hPa
Pollutant concentrations
SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Connection method
required front connector Yes
Mechanics/material
Type of housing (front)
Plastic Yes
Dimensions
Width 45 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 180 g